How do you calculate position tolerance?
Use the following formula to calculate radial hypotenuse value Multiply by 2 for the diametrical position tolerance. Diametrical Actual Tolerance = 2 X under root (0.15) square + (0.00) square. Therefore actual GD&T Position Tolerance measured against 0.25 is 0.30. The part is rejected.
True position can be calculated using the following formula: true position = 2 x (dx^2 + dy^2)^1/2. In this equation, dx is the deviation between the measured x coordinate and the theoretical x coordinate, and dy is the deviation between the measured y coordinate and the theoretical y coordinate.